| HS Code | 179331 |
| Productname | SikaFiber P/P 6 mm |
| Material | 100% polypropylene |
| Fibertype | Fibrillated synthetic polypropylene fiber |
| Fiberlength | 6 mm |
| Density | 0.91 g/cm³ |
| Meltingpoint | 160-170 °C |
| Ignitionpoint | >360 °C |
| Tensilestrength | >400 MPa |
| Elasticmodulus | >3500 MPa |
| Elongationatbreak | 15-20% |
| Waterabsorption | Nil |
| Alkaliresistance | Excellent |
| Acidresistance | Excellent |
| Thermalconductivity | Low |
| Electricalconductivity | Low |
| Corrosionresistance | Non-corroding |
| Magneticproperties | Non-magnetic |
| Color | Natural / white |
| Form | Fibrillated |
As an accredited SikaFiber P/P 6 mm - Polypropylene Fibers for Concrete and Mortars factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | SikaFiber P/P 6 mm is supplied in 900 g bags, 20 bags per carton (18 kg), for concrete and mortar reinforcement. |
| Container Loading (20′ FCL) | SikaFiber P/P 6 mm polypropylene fibers for concrete and mortars, palletized, shrink-wrapped, and loaded into a 20-foot FCL container. |
| Shipping | Shipping: SikaFiber P/P 6 mm is a non-hazardous, non-regulated polypropylene fiber supplied in sealed, moisture-resistant bags, usually palletized. No dangerous goods handling is required. Transport and store dry, away from direct sunlight and moisture. Standard parcel or freight services are suitable for deliveries. |
| Storage | Store SikaFiber P/P 6 mm in original, unopened bags in a dry, cool, well-ventilated area. Keep off the ground on pallets, away from moisture, direct sunlight, heat, and ignition sources. Protect packaging from damage and contamination. Avoid excessive stacking. Observe manufacturer’s shelf life and use first-in/first-out stock rotation. Ensure good housekeeping and prompt cleanup of spills. |
| Shelf Life | Shelf life is 24 months from production when stored dry, in original unopened packaging, protected from direct sunlight and moisture. |
SikaFiber P/P 6 mm is a microsynthetic polypropylene fibre supplied in fibrillated form for concrete and mortar. In ready-mixed concrete for large-area industrial ground slabs and external hardstandings, the fibre is specified primarily as plastic-shrinkage crack control. Addition rates fall between 0.6 kg/m³ and 0.9 kg/m³ for slab depths up to 300 mm; the upper range of 1.2 kg/m³ is occasionally used for exposed aggregate concrete where early surface tearing appears during screeding. Compliance sits under EN 206:2013+A2:2021 for concrete specification, while fibre performance is evaluated under EN 14889-2:2006 as a Class II microsynthetic polymer fibre with CE marking under Construction Products Regulation (EU) No 305/2011; ASTM C1116/C1116M Type III provides the equivalent North American classification, and ACI 302.1R-15 governs slab construction tolerances that interact with crack width control. Plastic-shrinkage cracking resistance can be evaluated by ASTM C1579-21, which applies a controlled drying regime to fresh mortar overlays. The production sequence at ready-mix plants involves metered addition of fibre pouches into the aggregate charging stream after coarse aggregate has passed through the weigh hopper gate but before cement enters the compulsory mixer. Twin-shaft mixers with batch volumes from 2.0 m³ to 3.5 m³ and shaft speeds of 15 rpm to 20 rpm are preferable because the low fibre mass and high surface area require the shear of moist aggregate flow rather than prolonged dry agitation. Truck-mixer charging should add fibre onto the aggregate stream at the plant with drum speed maintained at 12 rpm to 16 rpm during charging; adding fibre to dry cement before water is recognised as a batching error because electrostatic charge from polypropylene leads to wall adhesion and the formation of undispersed fibre clumps that can survive 90 seconds of normal mixing. The terminal products are warehouse floor slabs, container yard aprons, access pavements and agricultural hardstandings where saw-cut joints are installed at spacings reduced to 3 m to 4 m to accommodate early shrinkage strain relief.
| Application area | Typical addition range | Primary sustainability/compliance anchor | Core production equipment |
|---|---|---|---|
| Ready-mixed industrial floor slabs | 0.6–0.9 kg/m³ | EN 206:2013+A2:2021, EN 14889-2:2006, ASTM C1116/C1116M Type III | Twin-shaft compulsory mixer 15–20 rpm, truck mixer 12–16 rpm |
| Wet-mix shotcrete | 0.9–1.5 kg/m³ | EN 14487-1:2005, EFNARC 1996, ACI 506R-16 | S-valve piston pump, 50–65 mm delivery line, 25–60 bar |
| Precast tunnel segments | 1.5–3.0 kg/m³ | EN 1992-1-2:2004, ISO 834-1:1999, RWS curve, EN 14889-2:2006 | Carousel plant, twin-shaft compulsory mixer 1.5–3.0 m³ |
| Self-levelling underlayments and screeds | 0.4–1.2 kg/m³ | EN 13813:2002, EN 13892-1:2002, EN 14889-2:2006 | Ploughshare dry-mix mixer 80–120 rpm, progressing cavity pump 25–35 mm hose |
| Semi-dry pavers and masonry units | 0.5–1.0 kg/m³ | ASTM C936/C936M, ASTM C90, EN 1338:2003 | Block machine 40–60 Hz, compaction 0.1–0.3 MPa |
| Thin-section repair mortars | 0.5–1.0 kg/m³ | EN 1504-3:2005, EN 1542:1999, EN 12190:1998 | Paddle mixer 300–600 rpm, trowel or wet-spray application |
Wet-mix shotcrete for underground temporary support and permanent lining applications uses 0.9 kg/m³ to 1.5 kg/m³ of the 6 mm polypropylene fibre, with the lower bound selected for standard sprayed concrete and the upper bound for high-cement paste mixes exposed to rapid drying at the tunnel face. The governing standards are EN 14487-1:2005 for sprayed concrete specification, EFNARC 1996 for application and testing, and ACI 506R-16 for North American practice; fibre suitability is assessed under EN 14889-2:2006. In production, the fibre is introduced at the batch plant into a compulsory mixer running at 15 rpm to 20 rpm, then transported in ready-mix trucks to the shotcrete pump. Positive-displacement piston pumps with S-valve transfer tubes and 50 mm to 65 mm delivery lines are standard; pumping pressures between 25 bar and 60 bar force the fibre-containing concrete through the S-tube reversal zone, where 6 mm fibres are short enough to pass through the 65 mm discharge opening without accumulating at the valve blade. Field records from tunnel support operations show that at 1.5 kg/m³ nozzle blockages become more frequent when the pump is fitted with 50 mm nozzles and when aggregate with fine-particle content below 0.125 mm exceeds 450 kg/m³, because the paste phase coats the fibres into low-mass agglomerates under high-shear pumping. Compressed-air injection at the nozzle at 5 m³/min to 8 m³/min and air pressure of 4 bar to 6 bar disrupts any remaining fibre clusters before impact; rebound rates at 1.5 kg/m³ are typically 5 to 8 percentage points higher than plain shotcrete, and this should be controlled by lowering the distance between nozzle and substrate to 0.8 m to 1.2 m rather than by adding water. The terminal products are primary and final sprayed-concrete tunnel linings, rock slope stabilisation works, and shaft linings where early plastic shrinkage cracking at the flash-set surface must be reduced without changing the structural reinforcement layout.
For precast concrete tunnel segments exposed to RWS hydrocarbon fire conditions, the 6 mm polypropylene fibre functions not as structural reinforcement but as a pore-pressure relief mechanism. Addition rates of 1.5 kg/m³ to 3.0 kg/m³ are used, with 2.0 kg/m³ as the most common default in high-strength segmental concrete with compressive strength class C50/60 to C80/95 under EN 1992-1-1. The governing fire-spalling standards are EN 1992-1-2:2004 and ISO 834-1:1999 for standardised temperature-time exposure, while the Rijkswaterstaat RWS curve defines the severe hydrocarbon scenario in many tunnel specifications; the fibre itself is evaluated under EN 14889-2:2006. Segment production is performed on carousel or flow-line plants with twin-shaft compulsory mixers of 1.5 m³ to 3.0 m³ batch capacity. Mixing protocol adds fibres after the sand and coarse aggregate have been mixed with approximately 30% of the total water for 30 seconds to 45 seconds, allowing the fibre bundles to open in the moist aggregate phase before cementitious paste reaches full viscosity. In self-compacting segment mixes, adding 2.0 kg/m³ to 3.0 kg/m³ reduces slump flow measured to EN 12350-8:2019 by 40 mm to 90 mm and increases V-funnel discharge time by 1.5 s to 4 s; published data for this specific 6 mm fibre configuration remains limited, so pre-qualification with the actual mixer speed, aggregate humidity and aggregate absorption is necessary. The curing regime for segments usually involves formwork release at 12 hours to 16 hours and thermal curing at 40°C to 60°C for 6 hours to 10 hours; the polypropylene fibre has a melting point around 160°C to 170°C and remains solid during accelerated curing. Under fire, the fibre degrades and leaves pores of roughly 0.3 mm to 0.5 mm diameter, which lower internal pore pressure during rapid temperature rise and reduce explosive spalling of high-strength concrete. The terminal products are precast reinforced concrete tunnel lining segments for metro, road and water tunnels where project fire-safety requirements specify reduced spalling risk.
Self-levelling cementitious underlayments and pump-applied floor screeds incorporate the 6 mm polypropylene fibres at 0.4 kg/m³ to 0.8 kg/m³ for layer thicknesses from 3 mm to 10 mm, and at 0.9 kg/m³ to 1.2 kg/m³ for screeds in the 10 mm to 30 mm range. The applicable standards are EN 13813:2002 for screed material designation and EN 13892-1:2002 for determination of flexural and compressive strength; fibre compliance is assessed under EN 14889-2:2006. The dry-mix production route is more sensitive than wet-concrete batching because the fibre must be dispersed into a powdery matrix with low moisture content before the end user adds water. Horizontal ploughshare mixers with operating capacities up to 2,000 L and main-shaft speeds of 80 rpm to 120 rpm are used; the fibres are typically added after the fine aggregate and cement have been dry-mixed for 60 seconds, and the full dry blend is mixed for an additional 120 seconds. Experience from dry-mortar plants shows that adding fibre before the cement and fine aggregate causes electrostatic fibre aggregation on the mixer lid and filter socks, creating dosage variability; some plants therefore use a 1 m³ hopper with mechanical star feeder that doses fibre into the mixer through a side port under slight negative pressure. After mixing, the dry mortar is bagged or delivered to silo-based mobile mixing pumps. At the job site, the product is mixed with water in a continuous mixing pump, typically rotor-stator or progressing cavity, and pumped through 25 mm to 35 mm hoses. The 6 mm fibre length is close to the minimum clearance of some 25 mm hose end nozzles, so operators must ensure that nozzle reducers below 20 mm are not used when fibre is present. The terminal products are self-levelling underlayments, floor levelling compounds, and pumpable screeds for renovation of concrete and screed substrates.
Semi-dry concrete production for segmental pavers, block units and retaining wall elements operates at zero-slump consistency with moisture contents typically 5% to 8% by total dry weight. SikaFiber P/P 6 mm is added at 0.5 kg/m³ to 1.0 kg/m³ to reduce edge chipping during demoulding and mitigate plastic-shrinkage microcracking in thin webs between core voids. The product standards are ASTM C936/C936M for solid interlocking paving units, ASTM C90 for loadbearing concrete masonry units, and EN 1338:2003 for concrete paving blocks; fibre compliance is measured under EN 14889-2:2006 or ASTM C1116/C1116M Type III. Production uses block machines with vibration tables operating at 40 Hz to 60 Hz and compaction pressures from 0.1 MPa to 0.3 MPa, depending on unit height and aggregate packing. Fibres are introduced into the pan mixer or planetary compulsory mixer after the aggregate has been pre-wetted with process water but before the cement and supplementary cementitious materials are added; a mixing time of 90 seconds to 150 seconds is common. Because the mix contains insufficient water to separate fibres by immiscible liquid shear, dispersion depends on the mechanical action of moist sand particles between mixer blades and rotating pan. Batch plants report no measurable increase in water demand at 1.0 kg/m³, but at laboratory scale the compacted dry density may decrease by 5 kg/m³ to 15 kg/m³ when compared with an equivalent plain mix under the same compaction energy. The terminal products include interlocking pavers, concrete masonry units, segmental retaining wall blocks, and kerb units where the fibre reduces surface defects that otherwise create rework at the cubing and palletising stage.
Concrete repair mortars conforming to EN 1504-3:2005 classes R3 and R4 are formulated with 0.5 kg/m³ to 1.0 kg/m³ of the 6 mm polypropylene fibre when the application is a thin-section surface restoration over contaminated or carbonated concrete substrates. The standard framework includes EN 1504-10:2017 for site application and EN 1766:2017 for substrate preparation, while the fibre is covered by EN 14889-2:2006 as a Class II additive; compressive strength and adhesion are evaluated under EN 12190:1998 and EN 1542:1999 respectively. Site mixing is performed with paddle mixers or handheld compulsory mixers at 300 rpm to 600 rpm for 2 minutes to 3 minutes, and the fibre is commonly dry-blended with the mineral powder before the prescribed water dosage is added. When the repair is applied by trowel or wet-spray at substrate temperatures below 10°C, the fibre reduces early-age crack formation in thin layers of 5 mm to 20 mm, where free water escapes from the surface more rapidly than in mass concrete. With low-temperature application, the mixed mortar should be maintained at 5°C to 25°C during the first 24 hours and protected from wind speeds above 4 m/s to prevent surface crusting; fibre inclusion does not substitute for wet curing or curing membrane conforming to EN 13670:2009. The terminal products are structural and non-structural repair mortars for bridge piers, balcony edges, car park spalling repairs and industrial floor patch repairs.
Competitive SikaFiber P/P 6 mm - Polypropylene Fibers for Concrete and Mortars prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618112911328 or mail to sales1@liwei-chem.com.
We will respond to you as soon as possible.
Tel: +8618112911328
Email: sales1@liwei-chem.com
Flexible payment, competitive price, premium service - Inquire now!
SikaFiber P/P 6 mm is a discrete polypropylene monofilament fibre supplied for direct addition to cementitious concrete and mortar systems. The product is classified as a Class I polymer microfibre under EN 14889-2:2006, the harmonised European standard for polymer fibres for structural and non-structural concrete. Its nominal length is 6 mm and its declared diameter is below 0.30 mm, consistent with the microfibre category. The base polymer is isotactic polypropylene homopolymer with a typical density of approximately 0.91 g/cm³ when tested according to ISO 1183-1. In fresh concrete the product is chemically inert within the 12.5–13.5 pH range of cementitious pore solution and does not bind mixing water. The primary documented mechanisms are reduction of plastic shrinkage cracking through distributed crack bridging and reduction of fire-induced spalling through formation of pressure-relief channels after fibre melting. Under ASTM C1116/C1116M, the material is a synthetic microfibre and is not intended to replace primary reinforcement or to provide measurable post-cracking flexural capacity under ASTM C1609/C1609M. The product is CE marked under EN 14889-2:2006; project specifications should reference the product declaration of performance for the exact regulated values and tolerances.
Because polypropylene has a hydrophobic surface, the fibre does not require pre-wetting before batching. Its density is lower than water, so dry fibres may float on the surface of unagitated water if charged incorrectly; this behaviour governs the required mixing sequence. Storage in sealed bags is recommended because prolonged ultraviolet exposure can embrittle polypropylene. Outdoor bulk storage without protective covering is not advised for this fibre class. The material is non-corroding, non-magnetic, and electrically non-conductive, which separates it from steel fibre products in repair applications where corrosion-induced staining or electromagnetic interference is undesirable.
| Property | Standard or method | Typical value or Class I criterion |
|---|---|---|
| Nominal fibre length | EN 14889-2:2006 declared value | 6 mm |
| Fibre diameter | Microscopy | <0.30 mm |
| Polymer density | ISO 1183-1 | 0.91 g/cm³ |
| Melting range | ISO 11357-3 | 160 °C–170 °C |
| Free-fibre tensile strength | ISO 5079 or manufacturer declaration | 300 MPa–400 MPa for polypropylene monofilament class |
| Alkali resistance | EN 14889-2:2006 alkaline immersion method | No significant degradation in cementitious alkaline environment |
Plastic shrinkage cracking occurs when capillary tension in fresh concrete exceeds the developing tensile strength at the exposed surface. The condition is most severe during the first 6 h after placement, when evaporation rates are high, bleed water has not reached the surface in sufficient volume, and the material is still in the plastic state. Polypropylene microfibres act as a distributed network of low-modulus inclusions that bridge initial microcracks and redistribute capillary stress. The comparative test framework is ASTM C1579-21, which subjects restrained concrete panels to a controlled air velocity of approximately 4.7 m/s and elevated temperature to simulate worst-case evaporation conditions. Published product-specific crack data for SikaFiber P/P 6 mm is limited; independent studies on polypropylene microfibres of comparable geometry and dosage have reported crack area reductions in the range of 40% to 85% at 0.9 kg/m³. These reductions are specific to the test geometry and should not be transferred directly to field slabs without calibration.
In fire-spalling applications, the same fibre is specified at higher addition rates. Dense concretes with water-to-cement ratios below 0.35 and compressive strengths above 60 MPa are particularly vulnerable to explosive spalling because of low permeability and restricted vapour transport. Under rapid heating, free and chemically bound water migrates toward the heated surface, creating high pore pressure. Polypropylene fibres melt at approximately 160 °C to 170 °C and leave a network of microchannels that increases the permeability of the heated concrete. The relevant structural fire design framework is EN 1992-1-2; fire testing is performed under ISO 834-1 or classified under EN 13501-2. Published full-scale fire-test data for this exact 6 mm product is limited, and furnace test results for comparable microfibres do not scale linearly with slab thickness, aggregate type, moisture condition, or heating rate.
In central-mix batching plants using twin-shaft compulsory mixers, the fibre is introduced after aggregates and before cement or water. The aggregate shear opens the fibre bundles before wetting, which reduces agglomeration. If the product is discharged into a truck mixer after central mixing, the residual mixing time should be sufficient to maintain fibre distribution but not so long that excessive shear breaks the fibres. At dosages below 1.0 kg/m³, the effect on slump in a typical 100 mm to 150 mm slump concrete is generally less than 10 mm. At dosages above 1.5 kg/m³, the increased fibre surface area may require a mid-range water-reducing admixture conforming to EN 934-2 to restore workability. The fibre does not react with calcium chloride accelerators, but chloride-containing admixtures remain subject to EN 206 exposure class restrictions for reinforced concrete.
For air-entrained concrete, the addition of polypropylene fibres can influence the formation of the air-void system. Trial batches should include verification of air content and spacing factor under ASTM C457/C457M or EN 480-11 when freeze-thaw durability is specified. The product should be kept dry before use; moisture uptake in storage is minimal because polypropylene does not absorb water, but wet packaging can introduce handling issues.
Dispersion failure in free-fall drum mixers occurs because the low-shear core of the drum does not forcibly separate hydrophobic fibre bundles. Field records from production-scale batching show that fibre balls between 5 mm and 20 mm can form when the product is added directly to the water phase or to a completely dry mixer without aggregates. Once formed, these bundles are not broken down by ordinary drum rotation and may appear as surface defects in slab finishes. The corrective procedure is to pre-blend the fibres with 100 kg to 200 kg of coarse aggregate before charging. This step uses aggregate particles as mechanical dispersants. Twin-shaft compulsory mixers with rotor tip speeds in the range of 3 m/s to 5 m/s generally provide sufficient shear to eliminate fibre balling without excessive fibre breakage. For field verification, a 5 kg fresh concrete sample can be washed through a 0.50 mm sieve; retained fibre agglomerates indicate inadequate mixing. The fibre should not be added to an empty mixer because direct blade contact can produce short fibrils that do not provide the intended crack-bridging function.
The phase transformation of polypropylene at 160 °C to 170 °C is the critical parameter in fire-spalling mitigation. Before reaching this temperature, the fibres occupy the fresh and hardened matrix as discrete inclusions. During fire exposure, the fibre melts and is partially absorbed into the capillary porosity, leaving a connected network of channels. These channels increase the gas permeability of the heated concrete by opening routes for water vapour transport. The process is transient and occurs before the 200 °C to 300 °C temperature window in which explosive spalling is often observed in high-strength concrete. For spalling mitigation, fire research programmes commonly use dosages of 1.5 kg/m³ to 3.0 kg/m³ for microsynthetic polypropylene fibres. Published data for SikaFiber P/P 6 mm specifically is limited; most published evidence is based on equivalent polypropylene monofilaments of 6 mm to 12 mm nominal length. The product does not replace passive fire protection or reduce the minimum cover requirements of EN 1992-1-2. Section tests under ISO 834-1 remain necessary for project-specific validation because aggregate type, moisture content, and heating rate strongly influence spalling behaviour.
Microsynthetic fibres differ from macrosynthetic and steel fibres primarily in their post-cracking function. The 6 mm product is not assigned a residual strength class under ASTM C1609/C1609M; its contribution after matrix cracking is negligible at normal addition rates. Macrosynthetic polymer fibres conforming to EN 14889-2:2006 Class II and steel fibres conforming to ASTM A820/A820M provide load transfer across cracks of 0.5 mm to 3.5 mm. The following table summarises the main differentiating parameters.
| Parameter | SikaFiber P/P 6 mm microsynthetic | Class II macrosynthetic polymer fibre | Cold-drawn steel hooked-end fibre |
|---|---|---|---|
| Primary performance domain | Plastic shrinkage and settlement cracking, fire spalling mitigation | Post-cracking residual flexural capacity in hardened concrete | Post-cracking residual flexural and shear capacity in floor slabs and shotcrete |
| Typical addition rate | 0.6 kg/m³–3.0 kg/m³ | 2.5 kg/m³–9.0 kg/m³ | 15 kg/m³–60 kg/m³ |
| Residual strength under ASTM C1609/C1609M | Not applicable; no specified residual capacity class | Reported as equivalent flexural strength ratio at L/150 and L/600 | Reported as residual strength at L/150 and L/600 |
| Corrosion risk | None | None | Possible if cracks expose steel to chlorides |
| Thermal response | Melts at 160 °C–170 °C, creating pressure-relief channels | Melts at higher temperature; may not form channels before spalling | Strength degraded at temperatures above 400 °C |
Compared with fibrillated polypropylene fibre, the monofilament geometry of SikaFiber P/P 6 mm produces a finer dispersion in thin-section mortar and repair products. The product is suitable for use in precast concrete, slab-on-grade, shotcrete, and repair mortars where early-age crack control is the primary requirement. It is not a replacement for structural reinforcement, and crack-width calculations under EN 1992-1-1 or ACI 544.1R must not rely on the residual capacity of this fibre class. Steel fibres provide the highest residual strength but are heavier and susceptible to corrosion at crack locations subject to chloride ingress. Macrosynthetic fibres offer corrosion resistance and high toughness but require higher dosages to achieve equivalent residual strength. The 6 mm polypropylene microfibre does not compete in the residual strength domain and should not be specified where structural control of hardened cracks is required.
Under EN 14889-2:2006, the manufacturer maintains factory production control that tracks raw polymer lot identity, fibre geometry, tensile strength, alkali resistance, and effect on concrete consistency. The harmonised standard requires a declaration of the fibre’s nominal length, diameter, density, tensile strength, and conformity assessment. For SikaFiber P/P 6 mm, the CE mark and declaration of performance should be checked on receipt; the actual declared tolerances for length and diameter appear in the product certificate and should be compared with the project specification. Batch-to-batch variation in fibre length for this class is normally small, but unusual variation can alter dispersion in thin mortars. Where the product is specified for fire-spalling mitigation, standard fibre conformity testing is not sufficient to predict furnace performance; the designer may require additional tests under EN 13501-2 or ISO 834-1 using the intended concrete mix and section geometry.