| HS Code | 896250 |
| Material | 100% virgin polypropylene |
| Fibertype | Monofilament micro fiber |
| Length | 18 mm |
| Diameter | 20-30 µm |
| Aspectratio | 600-900 |
| Density | 0.91 g/cm³ |
| Tensilestrength | ≥400 MPa |
| Elasticmodulus | ≥3500 MPa |
| Elongationatbreak | 15-30% |
| Meltingpoint | 160-170 °C |
| Ignitionpoint | ≥590 °C |
| Waterabsorption | Nil |
| Acidresistance | Excellent |
| Alkaliresistance | Excellent |
| Color | White / natural |
| Recommendeddosage | 0.6-1.2 kg/m³ concrete |
| Thermalconductivity | Low |
| Electricalconductivity | Low |
| Uvresistance | Good |
As an accredited SINTA 18 mm - Monofilament Polypropylene Micro Fiber factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | SINTA 18 mm Monofilament Polypropylene Micro Fiber is supplied in 20 kg moisture-resistant woven bags, palletized for efficient shipping. |
| Container Loading (20′ FCL) | 20′ FCL container loaded with SINTA 18 mm monofilament polypropylene micro fiber, palletized and safely secured for ocean freight. |
| Shipping | SINTA 18 mm Monofilament Polypropylene Micro Fiber is shipped as a non-hazardous, non-regulated material. It is packaged in moisture-resistant bags or cartons, palletized, and secured for transport. Store in a cool, dry area away from direct sunlight, moisture, and ignition sources. No special transport classification required. |
| Storage | Store in a cool, dry, well-ventilated warehouse. Keep original containers sealed, labeled, and palletized off the floor. Protect from moisture, direct sunlight, heat, sparks, open flames, and strong oxidizers. Avoid dust generation, contamination, and physical damage. Use clean handling equipment and follow FIFO inventory. Do not smoke or eat in storage area. Dispose of damaged packaging properly. |
| Shelf Life | SINTA 18 mm monofilament polypropylene micro fiber: indefinite shelf life if stored dry, sealed, away from sunlight and extreme temperatures. |
Because automated logistics facilities impose strict floor flatness limits under DIN 18202 and ASTM E1155 F-number requirements, SINTA 18 mm - Monofilament Polypropylene Micro Fiber is batched at 0.9–1.2 kg/m³ into C30/37 floor concrete to suppress plastic shrinkage cracking during high-evaporation finishing windows. At the ready-mix plant, the fiber is discharged into the truck drum after aggregate and binder but before the final 20% of mixing water to reduce balling in 9 m³ loads; the drum is held at 6–8 rpm for a minimum of 5 minutes after fiber addition. On site, the concrete is placed by a 28 m truck-mounted pump, struck with a laser-guided screed, and finished with ride-on power trowels only after a surface bleed-water evaluation confirms the monofilament ends are no longer visible at the surface. The compliance path is EN 14889-2:2006 Class I synthetic micro-fiber for concrete and ASTM C1116/C1116M-23 Type III synthetic fiber-reinforced concrete. Finished goods include large-format jointless floor slabs for high-bay racking, automated guided vehicle travel routes, and cross-dock loading bays. The addition of fibers does not replace structural reinforcement; at 1.5 kg/m³ and above, slump loss of 20–40 mm has been observed in 0.45 water-to-cement-ratio mixes, and pumpability must be re-verified under ASTM C143/C143M rather than assumed. Published long-term crack-bridging data for this specific fiber length in simply supported slab flexure remain limited.
Shotcrete lining operations in NATM tunnel drives and underground mine development headings use SINTA 18 mm monofilament PP micro fiber at 0.9–1.5 kg/m³ during batching as a plastic shrinkage and rebound-control additive, and at 1.5–2.0 kg/m³ in high-strength sprayed concrete where hydrocarbon fire spalling mitigation is specified. The batching sequence adds the fiber to the compulsory twin-shaft mixer after fine aggregate but before the accelerator tank; the accelerator is dosed at the nozzle to prevent early adsorption on the fiber surface. Fresh sprayed concrete is tested under EN 14487-1:2005 for applicability and under EN 14889-2:2006 for fiber conformity; rebound is measured with the EFNARC 1996 spray trial method before the full advance is cleared. Production equipment includes a robotic spraying manipulator, a wet-mix shotcrete pump delivering through a 65 mm line at 30–60 bar, and a high-frequency poker vibrator for the initial lining; the nozzle distance is maintained between 0.8 m and 1.5 m to avoid fiber shadowing and rebound loss. Terminal outputs are initial and final tunnel linings, rock slope stabilisation shells, and shaft sealing layers; the material is not assigned structural macro-fiber load-bearing performance. When the dosage exceeds 2.0 kg/m³, pump line pressure often rises and nozzle rebound increases, requiring a field adjustment of hydration stabiliser. Published data for shotcrete residual flexural strength with 18 mm PP monofilament alone are limited; EN 14488-3 test results should not be used to certify structural energy absorption without a steel or macro-polymer fiber.
In zero-slump dry-cast paving block and kerb production lines, SINTA 18 mm - Monofilament Polypropylene Micro Fiber is weighed via an automated hopper and fed into a planetary counter-current mixer at 0.6–1.0 kg/m³ to reduce edge chipping during immediate demolding and to stabilize the surface against early evaporation after a 60°C heat-curing cycle. The fiber is added after coarse aggregate and pigment but before the final water; total mixing time is 120–180 seconds depending on aggregate moisture. The zero-slump concrete is placed into steel molds on a vibrating block machine at 35–50 cycles/min, compacted under 10–15 kN of header force, and demolded to the production pallet. Demolded components include concrete block paving units conforming to EN 1338:2003, kerbs and channels conforming to EN 1339:2003, and segmental retaining wall units. Factory quality control includes weekly saturated surface-dry aggregate moisture checks and a 2-hour oven-dry unit weight check. At fiber doses above 1.2 kg/m³, surface fiber visibility may increase after shot blasting; therefore the maximum addition should not exceed 1.0 kg/m³ where a fine-grained face mix is specified. The fiber is not considered to contribute to the split tensile strength under EN 1338.
A continuous screed mixing pump with a 120–180 L hopper and 25–35 L/min output requires the addition of SINTA 18 mm monofilament polypropylene fiber at 0.5–1.0 kg/m³ during continuous mixing to reduce early-age surface crazing and to maintain homogeneous suspension of lightweight aggregates. The dry blend is pre-mixed in a gravity-fed silo before the fiber is pneumatically conveyed into the hopper; the wet mix is discharged through a 20–30 m rubber hose and rolled with a porcupine roller to release entrapped air before the setting window. Compliance is under EN 13813:2002 for calcium sulfate and cementitious screed materials, with additional verification of consistency against the manufacturer’s declared class. Placed floor categories include bonded and unbonded cementitious screeds, floating screeds over insulation for underfloor heating, and thin self-leveling wear slabs. At fiber dosages above 1.0 kg/m³, the viscosity increase may reduce the flow cone spread by 20–40 mm, requiring additional superplasticizer within the EN 934-2 dosage cap. The fiber does not improve compressive strength and should not be counted toward the mechanical class of the screed.
For trowel-applied polymer-modified repair mortars and formed concrete patches, SINTA 18 mm - Monofilament Polypropylene Micro Fiber is added at 0.3–0.8 kg/m³ to the dry blend in a factory paddle mixer before bagging; on site, the powder is mixed with the specified polymer dispersion or water for 3 minutes at 400–600 rpm in a low-speed forced-action mixer. The addition ratio is kept below 1.0 kg/m³ because the high yield stress of R4-class repair mortars produces fiber balling during hand mixing. The production process includes surface preparation by grit blasting to a minimum roughness, application of a bonding primer, and compaction in 20–40 mm layers with a trowel or wet spray; the fresh mortar is tested against the manufacturer’s prescribed consistency. Compliance is assessed under EN 1504-3 Class R4 for structural repair and ASTM C928/C928M for packaged dry repair mortars. Approved patch categories include overhead and vertical concrete repair patches, formed column repairs, and bridge deck spall repairs. The fiber is introduced only to control plastic shrinkage in low-thickness patches; it is not a replacement for reinforcing bars in the composite repair system. Where crack bridging or dynamic movement is required, the design must reference EN 1504-3 Table 1 performance requirements for structural repair products and conduct testing under the relevant method; published data for single-component patching mortars containing 18 mm PP monofilament in moving cracks are limited.
Vertical dry-cast concrete pipe and box culvert production lines meter SINTA 18 mm - Monofilament Polypropylene Micro Fiber into the concrete at 0.5–0.9 kg/m³ in a stationary planetary mixer before the zero-slump mix is fed into a vertical pipe machine or box culvert mold with external vibrators running at 50–100 Hz. The fiber reduces spalling at the spigot and collar edges during demolding and yard handling, but the steel reinforcement cage remains the primary load-bearing element. Compliance is specified by ASTM C76 for reinforced concrete culvert, storm drain, and sewer pipe and by EN 1916:2002 for concrete pipes and fittings. Ex-works precast elements include reinforced concrete pipe, precast box culverts, and utility tunnel segments. At dosages above 1.0 kg/m³, the fiber can agglomerate at the pipe wall, causing surface defects; pre-drying of the fiber is required at ambient relative humidity above 60% because moisture bridges the monofilament bundles before charging. The fiber is not intended to alter the structural design or to replace steel cages in buried infrastructure.
Competitive SINTA 18 mm - Monofilament Polypropylene Micro Fiber prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618112911328 or mail to sales1@liwei-chem.com.
We will respond to you as soon as possible.
Tel: +8618112911328
Email: sales1@liwei-chem.com
Flexible payment, competitive price, premium service - Inquire now!
SINTA 18 mm - Monofilament Polypropylene Micro Fiber is a discrete synthetic filament additive for cementitious mixtures. The material is a single-strand polypropylene monofilament, not a fibrillated tape, supplied at a nominal cut length of 18 mm. In concrete technology it is classified as a Class I polymer micro fibre under EN 14889-2:2006 because the equivalent filament diameter is below 0.30 mm. At a nominal diameter of 18 µm to 30 µm and a polymer density of 0.91 g/cm³, the calculated filament count is approximately 86 million to 240 million filaments per kilogram. Production involves melt-spinning of polypropylene, controlled drawing to orient the polymer chains, and precision cutting to length. Unlike steel fibers, the monofilament is non-corrosive and does not significantly alter the magnetic or electrical conductivity of concrete. Unlike macro-synthetic fibers, the micro fiber is not intended to provide post-crack residual flexural capacity under EN 14651 or ASTM C1609/C1609M; its function is limited to bleed-water control, plastic settlement reduction, and fire-induced spalling permeability.
Lot conformity for a polymer micro fibre is assessed under EN 14889-2:2006, with the product designated Class I where the equivalent diameter is less than 0.30 mm. Under the U.S. specification, concrete containing the fibre is classified as Type III synthetic fibre-reinforced concrete under ASTM C1116/C1116M-23. The values in the table are representative of an 18 mm monofilament polypropylene micro fiber; they are not a substitute for the manufacturer certificate of analysis.
| Property | Typical value or range | Reference method or basis |
|---|---|---|
| Product form | Monofilament, cut filament | Manufacturer designation |
| Nominal cut length | 18 mm | Manufacturer designation |
| Equivalent diameter | 18–30 µm | Product class; certificate of analysis governs |
| Specific gravity | 0.91 | ISO 1183-1:2019 |
| Tensile strength | 300–500 MPa | EN 14889-2:2006 Annex B fibre test |
| Elastic modulus | 3.5–4.5 GPa | Fibre test per certificate |
| Elongation at break | 15–25 % | Fibre test per certificate |
| Melting temperature | 160–170 °C | ISO 11357-3:2018 |
| Water absorption | <0.1 % | ASTM D570-98(2021) |
| Alkali stability | No chemical degradation at pH 12–13 | Polypropylene inert in non-oxidizing alkaline media |
The batching system should discharge the fiber within the aggregate weigh hopper or after aggregate transfer. Gravimetric dosing equipment with an accuracy of at least ±0.1 kg is required for dosages at 0.9 kg/m³; volumetric dosing is acceptable only if calibrated against fiber bulk density. Bulk density of chopped monofilament polypropylene can vary from 0.35 g/cm³ to 0.45 g/cm³ depending on packing and filament stiffness, so a loss-in-weight feeder should be calibrated for each bulk bag lot. At 0.9 kg/m³, the water demand is small; however, the high filament count increases total surface area, and slump loss of 10–30 mm has been reported when high-range water reducers are used without dosage adjustment. The product is added before or during initial mixing; extending mixing time beyond 120 s after fiber addition has not shown improved dispersion in published data for similar monofilaments, and may increase fiber breakage.
In high-shear mixing, the separation of monofilaments is governed by mixer speed, drum fill ratio, and filament surface energy. Twin-shaft compulsory mixers with rotor tip speeds of 2.0 m/s to 3.0 m/s distribute an 18 mm monofilament more consistently than gravity mixers, which may require longer dry-mixing intervals of 30–60 s before water addition. Balling in pan mixers is reported when fibers are introduced before aggregate or directly onto a wet batch. A batching sequence that places the fibers on the aggregate belt, between coarse aggregate and cement, reduces clumping because mechanical interlocking of the monofilament with wet fines is postponed. For ready-mixed concrete trucks, adding the bagged fiber directly to the drum at the plant and mixing at 12–18 rpm for 40–60 revolutions is commonly specified; published data for this specific configuration is limited, and a visual washout test of a fresh sample should be performed to confirm individual filament presence. The fiber does not affect setting time under ASTM C403/C403M and does not contribute to air-entrainment instability when dosed with air-entraining admixtures meeting ASTM C260/C260M or EN 934-2, although high dosages can reduce the spacing factor by increasing paste viscosity.
The primary use of 18 mm monofilament polypropylene micro fiber is the reduction of plastic shrinkage cracking in concrete slabs, pavements, screeds, and sprayed concrete linings. Under the restrained panel method of ASTM C1579-21, polypropylene micro fibers at 0.6–1.0 kg/m³ have been reported to reduce crack area by 50 % to 85 % relative to plain concrete, with the exact reduction controlled by evaporation rate, concrete depth, and paste volume. The mechanism is not an increase in tensile strength; the fiber network increases the apparent strain capacity of the fresh paste and arrests microcrack propagation by reducing plastic settlement and capillary pressure. Because monofilament polypropylene has an elastic modulus of only 3.5–4.5 GPa, it cannot bridge hardened cracks as steel or macro-synthetic fibers do, and its contribution to post-crack residual strength under EN 14651 or ASTM C1609/C1609M is negligible at dosages below 1.8 kg/m³.
In high-strength or dense concretes, the fiber is used to mitigate explosive spalling under fire exposure. At temperatures between 160 °C and 170 °C, the polypropylene filaments melt and form interconnected channels that increase the permeability of heated concrete. The resulting permeability increase allows water vapor pressure to dissipate; this effect is dosage-dependent and is generally specified at 1.5–3.0 kg/m³ for high-performance concrete exposed to hydrocarbon fire curves such as ISO 834-1:1999. The precise dosage must be determined by furnace testing because excessive polypropylene can increase residual porosity and reduce compressive strength after cooling.
Storage of SINTA 18 mm must avoid direct UV exposure, moisture ingress, and compression damage. Polypropylene is hydrophobic, with water absorption below 0.1 % under ASTM D570-98(2021), but surface moisture can cause filaments to clump or packaging to tear if stored in saturated conditions above 60 % relative humidity. Partially used bags should be resealed and used within the manufacturer-stated shelf life, commonly 24 months from production when stored at 5–40 °C. The product should not be combined with solvent-based curing compounds or aromatic hydrocarbons before mixing, because polypropylene swells in the presence of chlorinated and aromatic solvents. The fiber is chemically stable in the alkaline pore solution of concrete with pH 12–13; it does not hydrolyze like polyester fibers and does not rust like steel fibers. However, polypropylene is vulnerable to strong oxidizing acids, and is not recommended for concrete exposed to continuous high-temperature service above 100 °C, where polymer softening precedes melting and volatile release may occur.
Selection between monofilament and fibrillated polypropylene micro fibers is determined by dispersion characteristics, exposed-surface finish, and crack-reduction testing under ASTM C1579-21. A monofilament cut to 18 mm has a defined cylindrical cross-section, whereas a fibrillated tape fiber is initially a flat film that splits into interconnected fibrils during mixing. At equal mass dosage, the monofilament typically yields a higher number of discrete filaments per kilogram and a lower visible fiber density on troweled surfaces, but published data for the present product is limited; comparative laboratory trials are recommended. In precast facades and architectural concrete, the monofilament may be preferred because the smaller individual diameter leaves less surface fuzz after acid etching or form stripping. However, fibrillated tapes can provide a larger surface area per fiber mass and may be more efficient in certain mixers if they open fully; if the mixer energy is low, unopened fibrillated fibers can remain as visible tape fragments.
| Attribute | SINTA 18 mm monofilament PP micro fiber | Fibrillated PP micro fiber | Steel hooked-end macro fiber | Macro-synthetic fiber |
|---|---|---|---|---|
| Primary function | Plastic shrinkage crack reduction; fire spalling mitigation | Plastic shrinkage crack reduction | Structural crack width control; post-crack flexural strength | Post-crack ductility; shrinkage and temperature reinforcement |
| Length | 18 mm | 12–19 mm | 30–60 mm | 40–65 mm |
| Equivalent diameter | 18–30 µm | 50–100 µm tape equivalent | 0.5–1.0 mm | 0.3–1.0 mm |
| Tensile strength | 300–500 MPa | 300–450 MPa | 1000–1500 MPa | 400–600 MPa |
| Elastic modulus | 3.5–4.5 GPa | 3.5–4.0 GPa | 200 GPa | 5–10 GPa |
| Density | 0.91 g/cm³ | 0.91 g/cm³ | 7.85 g/cm³ | 0.92–0.95 g/cm³ |
| Typical dosage | 0.6–1.8 kg/m³ | 0.6–1.8 kg/m³ | 20–40 kg/m³ | 3–9 kg/m³ |
| Fire spalling behavior | Melts at 160–170 °C; increases permeability | Melts at 160–170 °C; increases permeability | No melting; limited effect on spalling permeability | Melts or softens; may increase permeability at high dosage |
The contrast with macro-synthetic fibers is functional as well as dimensional. Macro fibers at lengths of 40–65 mm and diameters of 0.3–1.0 mm are used at dosages of 3–9 kg/m³ to provide post-crack flexural strength, with residual flexural strength classes defined under EN 14889-2:2006 and test methods in EN 14651 or ASTM C1609/C1609M. The 18 mm polypropylene micro fiber does not replace such macro reinforcement; it is sometimes combined with macro-synthetic or steel fibers when both plastic-shrinkage control and hardened-state ductility are required. The total fiber volume must then account for paste availability, because both fiber classes increase the demand for workability and may require high-range water reducers.
Quality control of SINTA 18 mm on project sites includes verification of bag weight, nominal length, and visual dispersion in fresh concrete. A washout test using a 5 kg sample may be performed on the first mixer, with the water added through a 0.075 mm sieve to retain fibers. The recovered mass should be compared with the expected fiber mass for the sampled volume; deviations greater than ±5 % require an inspection of the dosing gate and mixing speed. Mechanical property tests are generally not required for microfibers at low dosage. Acceptance should reference the manufacturer certificate, EN 14889-2:2006 CE marking where applicable, and the project specification. When the product is used for fire spalling mitigation, a furnace test of the exact mix design should be carried out before production because cement type, aggregate moisture, and silica fume content alter the required dosage. No additional curing temperature or maturity restrictions apply beyond those for the base concrete, but the use of polypropylene fiber does not reduce the minimum curing period specified by ACI 308 or EN 13670.