Liwei Group Co., Ltd

Products

SINTA M3106 - Micro-Synthetic Polypropylene Fiber for Concrete

    • Product Name: SINTA M3106 - Micro-Synthetic Polypropylene Fiber for Concrete
    • Factroy Site: West Ujimqin Banner, Xilingol League, Inner Mongolia, China
    • Price Inquiry: sales1@liwei-chem.com
    • Manufacturer: Liwei Group Co., Ltd
    • CONTACT NOW
    VTB
    Specifications
    HS Code 519634
    Material 100% virgin polypropylene
    Fiber Type Micro-synthetic polypropylene fiber
    Appearance Monofilament
    Color White
    Fiber Length 6 mm
    Fiber Diameter 18-30 μm
    Aspect Ratio 200-333
    Density 0.91 g/cm³
    Specific Gravity 0.91
    Tensile Strength ≥400 MPa
    Elastic Modulus ≥3500 MPa
    Elongation At Break 15-30%
    Melting Point 160-170 °C
    Ignition Point ≥590 °C
    Acid Resistance Excellent
    Alkali Resistance Excellent
    Chemical Resistance Excellent
    Water Absorption Nil
    Uv Resistance Good
    Thermal Conductivity Low
    Electrical Conductivity Low
    Dispersibility Excellent
    Crack Resistance Improves plastic shrinkage cracking
    Recommended Dosage 0.6-1.2 kg/m³

    As an accredited SINTA M3106 - Micro-Synthetic Polypropylene Fiber for Concrete factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing SINTA M3106 micro-synthetic polypropylene fiber comes in 18 kg cartons containing twenty 0.9 kg water-soluble bags.
    Container Loading (20′ FCL) 20′ FCL loading: palletized SINTA M3106 micro-synthetic polypropylene fiber bags for concrete, securely strapped, shrink-wrapped, and stabilized for safe transport.
    Shipping SINTA M3106 is typically a non-hazardous polypropylene fiber supplied in moisture-resistant bags or cartons on pallets. It is not regulated for transport by DOT, IMDG, or IATA. Ship in clean, dry vehicles; keep containers closed, avoid sunlight, punctures, and moisture. Handle with standard PPE.
    Storage Store SINTA M3106 in a cool, dry, well-ventilated area, away from direct sunlight, heat, sparks, and open flames. Keep original bags sealed, off the ground on pallets, protected from moisture and contamination. Avoid excessive stacking. Maintain good housekeeping to prevent dust accumulation. Use first-in, first-out stock rotation. Do not store near strong oxidizers, acids, or incompatible materials. Follow local regulations and manufacturer’s SDS.
    Shelf Life Shelf life: 24 months from manufacture if stored unopened, dry, protected from moisture and sunlight; consult supplier for extended storage.
    Application of SINTA M3106 - Micro-Synthetic Polypropylene Fiber for Concrete

    Data logged from twin-shaft compulsory mixers producing 0.85–0.90 water-to-cementitious ratio ready-mix slab batches show that dosing SINTA M3106 at 0.9 kg/m³ equivalent to 0.1% by volume after coarse aggregate transfer but before the first 80% of mixing water is added prevents monofilament balling at the discharge gate. Dispersion is checked at the chute by washing 5 kg of fresh concrete through a 4.75 mm sieve; retained fibre agglomerates above 3 clumps/kg require an additional 90 s of mixing at 18–20 rpm in the truck drum. The fibre falls under synthetic fibre-reinforced concrete Type III according to ASTM C1116/C1116M-23 and must meet the dimensional and conformity requirements of EN 14889-2:2006 for Class I micro-synthetic fibres intended to control plastic shrinkage, not structural crack-width control after hardening. The nominal diameter of 32 µm and length of 12 mm place the product in the micro-fibre range where the filament count per cubic metre at 0.9 kg/m³ is approximately 1.0 × 10⁸ individual fibres, which is the relevant dispersion parameter for early-age bleed-water migration and capillary tension resistance.

    For external hardstand and warehouse floor placements, the downstream process includes pump spreading through a 36 m boom pump at 28–32 m³/h, followed by laser screed strike-off and power trowel finishing when the surface moisture film disappears. The fibre does not alter the finishing window provided the dosage remains below 1.2 kg/m³; above this threshold, published field reports from laser-screed operations indicate surface trowelling can expose monofilament tips if pulverisation is incomplete. Plastic shrinkage crack reduction is verified under ASTM C1579-21 in a climate chamber at 36–38°C, 55–60% relative humidity, and 0.8 m/s air velocity; comparative data for monofilament microfibres in ordinary Portland cement systems typically show crack area reduction in the 40–80% band relative to plain control, though published data for SINTA M3106 under site-specific concrete matrix conditions is limited. Terminal finished products are pump-cast mezzanine decks, warehouse floor slabs, external hardstands, and light-vehicle yard pavements.

    What Changes in Green-Strength Handling When SINTA M3106 Enters Segmental Lining Concrete?

    During demoulding and stack transport of precast tunnel segments, carousel plants record a measurable shift in edge integrity when 1.5 kg/m³ of SINTA M3106 is introduced into a 0.35 water-to-cementitious ratio mix containing 420 kg/m³ Portland cement and 40 kg/m³ silica fume. The fibre’s role is not structural; it reduces the tendency of green concrete to chip along segment edges during lifting from the mould at compressive strengths of 0.6–0.9 MPa. Production-scale experience from plants with 1.5 m³ pan mixers shows that the fibres must be added after fine aggregate and before cementitious powder to avoid accumulation in the paddles; addition with silica fume increases the incidence of static agglomerates because the high specific surface area of the silica fume competes for free water. The compaction sequence uses external high-frequency vibration at 50–65 Hz applied for 20–30 s per mould, followed by steam curing with a temperature ramp not exceeding 20 K/h to a core hold of 55°C at relative humidity above 85%. For fire spalling control, the dosage is raised to 2.0 kg/m³, and the mix is qualified under EN 1992-1-2:2004 national annex together with a project-specific RWS curve; the polypropylene fibres melt at approximately 160–170°C and create pressure-relief channels in the cement matrix, but project-specific fire tests remain mandatory before tunnel acceptance. Terminal products are precast segmental rings for tunnel boring machine drives and rectangular shaft liners.

    Standard / design basisProperty evaluatedAcceptance envelope for segment mixesProduction frequency
    EN 13369:2018Precast concrete product controlDimensional tolerance and mix certification per projectBatch / daily
    EN 1992-1-2:2004 + project RWSExplosive spalling under fire loadSpalling depth not more than 25 mm or reinforcement temperature not more than 500°CType test / material change
    EN 12350-2:2019Consistency after fibre addition120–160 mm slumpPer truck / batch

    Wet-Mix Shotcrete for Rock Support: Fibre Dosing and Rebound Management

    At the tunnel face, wet-mix shotcrete is supplied through diesel-hydraulic piston pumps and applied through a 65 mm rubber delivery line with a nozzle outlet pressure of 3.5–4.5 bar. The addition of 1.2 kg/m³ of SINTA M3106 to a 400 kg/m³ cement mix with 0.45 water-to-cementitious ratio improves plastic-phase cohesion and reduces edge sloughing on vertical rock substrates, but rebound follows a non-linear response: at 1.8 kg/m³ rebound loss may plateau while line pressure increases by 1.5–2.0 bar, producing pulsation at the nozzle. Spraying is conducted with a robotic manipulator maintaining 300–350 mm nozzle distance and 90° ± 10° spray angle, building layers of 50–80 mm per pass; the accelerator is delivered at the nozzle at 6–8% by cement mass. Compliance is governed by EN 14487-1:2005 for sprayed concrete and ACI 506R-16 for practice; material certification follows ASTM C1436-13 for shotcrete materials. Terminal finished products are rock stabilization linings, slope support shells, shaft collars, and temporary tunnel support arches. The fibre is not a substitute for macrosynthetic or steel fibres when toughness or energy absorption requirements exceeding the applicable EFNARC threshold are specified; the micro-fibre contributes mainly to plastic shrinkage cracking control and plastic-phase cohesion.

    Production records from continuous wet-mix units operating at 8–12 m³/h show that fibres must be added at the batch plant, not in the hopper; dry addition through the hopper screen causes bridging in the feed auger when residual moisture exceeds 0.2%. Short fibre wetting times are insufficient in high-intensity continuous mixers, and a minimum in-mixer residence time of 45 s after fibre addition reduces nozzle pulsation by maintaining uniform suspension.

    In self-smoothing cementitious underlayments, the interplay between fine-particle rheology and filament dispersal determines whether a 0.7 kg/m³ addition of SINTA M3106 creates surface streaks or passes through the pumping train without segregation. The binder typically consists of calcium aluminate cement and ordinary Portland cement with calcium aluminate below 25% of total binder, plus latex powder or methylcellulose-ether admixtures controlling bleed and open time. Under EN 13813:2002, the hardened layer is specified for compressive strength class C25/F7 or higher depending on the flooring system; published data for SINTA M3106 in polymer-modified smoothing compounds is limited, so plant trials should verify flow, open time, and fibre visibility using a flow table spread of 240–260 mm per EN 12706:1999. The downstream process comprises dry-mix blending in a horizontal ribbon blender, on-site batching with a forced-action mixer, pumping at 12–20 l/min through a rotor/stator pump, and de-aeration with a spike roller before the material gels. Terminal products are self-leveling underlayments beneath resilient flooring, floating floor sub-bases, and thin-section cementitious screeds in renovation work. Addition above 1.0 kg/m³ can reduce flow spread and produce surface fibril protrusion under polished or transparent floor finishes.

    Façade Panel Surface Defect Reduction and Mix Handling in Low-Slump Precast

    Before pigment paste is dosed into a low-slump façade mix, the addition of 1.0 kg/m³ of SINTA M3106 is made in a planetary high-shear mixer to restrict fine-crack formation at window corners and return edges during demoulding and transport. Reversing this order can produce localised pigment adsorption and visible fibre shadowing on acid-etched or exposed aggregate finishes. Vibratory consolidation uses form-mounted external vibrators at 60–100 Hz and 0.5–1.5 g acceleration for 10–20 s, after which the form face is examined under raking light for fibre migration. The applicable product standard is EN 13369:2018 with additional project requirements from façade technical approvals; where US project specifications apply, ASTM C1386-07 may be referenced alongside PCI MNL 116 for architectural precast production practices. Terminal products are architectural cladding panels, spandrel units, full-height façade assemblies, and precast cornices. Dosages exceeding 1.5 kg/m³ are operationally limited because high-frequency vibration can push fibres toward the mould surface, producing unacceptable surface roughness in exposed concrete.

    When Differential Deformation Drives Repair Mortar Cracking in Bridge Overlays

    After hydrodemolition profiling creates a rough, saturated bridge deck substrate, repair mortar placed over the irregular concrete cracks at the interface when the overlay is restrained by older concrete or steel anchors. In these applications, 1.2 kg/m³ of SINTA M3106 is introduced into a low-water-cement-ratio mortar with 0.35 water-to-cement ratio, containing 450 kg/m³ cementitious binder and 10% silica fume replacement, to suppress plastic shrinkage cracks during the first 6–8 h after placement. The material is mixed in a paddle or high-shear colloidal mixer for 3–5 min, pumped at low pressure through a 25 mm hose and placed in lifts of 25–40 mm; the open surface is kept moist or covered with curing compound to maintain internal relative humidity above 85% for 7 days. Compliance for the repair system is established under EN 1504-3:2005 class R4 for structural repair or ASTM C928/C928M-20 for packaged concrete repair materials; restrained shrinkage can be evaluated according to ASTM C1581-18 using ring specimens, and published data for SINTA M3106 under overlay-specific restrained conditions is limited. Terminal finished products are hydrodemolished bridge deck overlays, abutment cap repairs, column patch repairs, and structural bonding overlays.

    Free Quote

    Competitive SINTA M3106 - Micro-Synthetic Polypropylene Fiber for Concrete prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please contact us at +8618112911328 or mail to sales1@liwei-chem.com.

    We will respond to you as soon as possible.

    Tel: +8618112911328

    Email: sales1@liwei-chem.com

    Inquiry

    Get Free Quote of Liwei Group Co., Ltd

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    SINTA M3106 is a micro-synthetic polypropylene fiber produced for controlled dispersion in cementitious mixtures at addition rates from 0.6 kg/m³ to 1.8 kg/m³. The fiber is manufactured from 100% virgin polypropylene homopolymer and is supplied as a fine monofilament with nominal cut lengths of 6 mm or 12 mm. Filament diameter is controlled within 18 µm to 32 µm. The product falls under Type III synthetic fiber in ASTM C1116/C1116M-23 and is subject to conformity assessment under EN 14889-2:2006 for polymer fibers used in concrete. Applications include interior and exterior slabs-on-grade, precast panels, shotcrete linings, bridge deck overlays, and residential basement slabs where plastic shrinkage crack control is specified. The primary documented function is reduction of plastic shrinkage cracking and early-age settlement cracking in flatwork and restrained sections.

    The technical data sheet lists filament tensile strength as not less than 300 MPa when tested in accordance with EN 14889-2:2006. Elastic modulus is reported in the range 3.5 GPa to 4.2 GPa, and melt temperature is 160 °C to 170 °C per ISO 11357-3:2018. These values place SINTA M3106 in the low-modulus polymer fiber class. Elastic modulus is approximately one-tenth that of polypropylene macro-synthetic fiber and one-fiftieth that of steel fiber. Consequently, dosage increases above 1.8 kg/m³ generally do not produce proportional improvements in hardened-state flexural capacity and may reduce workability without a corresponding performance gain. The product does not replace steel reinforcing bars, welded-wire reinforcement, or macro-synthetic fibers where residual flexural strength is required.

    What Standard Test Framework Applies to Micro-Synthetic Polypropylene Fiber for Concrete?

    Specification of SINTA M3106 in concrete requires standard test procedures that distinguish fiber type, dosage verification, and plastic shrinkage performance. ASTM C1116/C1116M-23 establishes material requirements for Type III synthetic fiber-reinforced concrete and references ASTM C143/C143M slump testing and ASTM C231/C231M air content testing for fresh concrete acceptance. European contract specifications normally require a manufacturer’s Declaration of Performance under EN 14889-2:2006, which defines conformity for polymer fibers for concrete and sets tolerances for cut length, fiber count, and tensile strength. For plastic shrinkage crack evaluation, ASTM C1579-21 uses a restrained panel geometry and controlled evaporation rate to compare crack width and crack area reduction against a plain reference mixture.

    Specification guidance for SINTA M3106 establishes dosage verification based on fiber count in the paste fraction. When the product is added at 0.9 kg/m³, the projected fiber distribution in the paste is sufficient to bridge bleed-water channels during the first 6 h to 8 h after casting, but this effect is not directly measurable by standard compressive strength testing. Acceptance therefore relies on visual fiber dispersion checks, plastic shrinkage testing where specified, and batch weight documentation rather than standard hardened concrete strength specimens.

    SINTA M3106 technical data summary
    PropertyTest method or specificationTypical value or requirement
    Base polymerInfrared spectroscopy100% virgin polypropylene homopolymer
    Specific gravityISO 1183-1:20190.91 g/cm³ ± 0.01
    Cut lengthEN 14889-2:20066 mm and 12 mm, tolerance ± 10%
    Filament diameterOptical microscopy18 µm to 32 µm
    Tensile strengthEN 14889-2:2006≥ 300 MPa
    Modulus of elasticityISO 527-1:20193.5 GPa to 4.2 GPa
    Melt temperatureISO 11357-3:2018160 °C to 170 °C
    Water absorptionASTM D570-22< 0.1% by mass
    Moisture contentGravimetric≤ 0.5%
    Fiber count per kg, 12 mm at 22 µmCalculated from diameter and cut length≈ 2.4 × 10⁸
    Fiber count per kg, 6 mm at 22 µmCalculated from diameter and cut length≈ 4.8 × 10⁸

    Batch integration records from central mixers with capacity 2 m³ to 8 m³ and ready-mix truck drum mixers indicate that SINTA M3106 disperses most reliably when added to the aggregate stream before or during cement charging. Direct addition of dry fiber to the surface of a charged truck drum at low slump can create localized fiber balls, particularly when slump is below 100 mm and drum rotation is below 12 rpm. The product is supplied in degradable paper bags or bulk sacks. Whole bags may be introduced directly into a central mixer after 70% to 80% of batch water has been added, provided the mixing cycle continues for at least 4 min to 5 min at high shear. For truck mixer addition, the batching sequence normally specifies addition at the plant charging hopper to avoid fiber clumping on drum fins.

    In twin-shaft mixers operating at 35 rpm to 45 rpm pan speed, the product can be added without extending the standard wet mixing time when aggregate moisture content is greater than 2%. At aggregate moisture content below 1%, a pre-wetting sequence of 10 s to 15 s with part of the batch water before charging fiber reduces static charge and improves distribution. Slump reduction at 1.8 kg/m³ is typically reported in the range 10 mm to 25 mm relative to the same mixture without fiber. If the target slump is below 150 mm, a high-range water reducer may be required to compensate.

    Plastic Shrinkage Crack Control and Early-Age Settlement Mechanisms

    Plastic shrinkage cracking occurs when capillary tension in the freshly placed paste phase exceeds the tensile capacity of the weak early-age matrix. SINTA M3106 filaments create a fine network that reduces the rate of bleed-water evaporation from the surface and interrupts crack propagation before crack widths reach visible thresholds. In ASTM C1579-21 restrained panel tests conducted at 30 °C and 40% relative humidity with an evaporation rate of 0.5 kg/m²/h, published reports for polypropylene micro-synthetic fibers at 0.9 kg/m³ commonly document 40% to 80% reduction in crack area compared with the same mixture without fiber. Results vary with cement content, aggregate grading, and finishing operations, and the test is comparative rather than a direct prediction of field crack width.

    The fiber network also alters settlement behavior in deep sections. For slab depths greater than 150 mm, differential settlement over embedded reinforcement or sudden changes in section thickness can produce settlement cracking. The fine monofilament phase reduces localized strain concentration in the upper paste layer. This effect is distinct from hardened-state drying shrinkage control, which is not provided by low-modulus polypropylene microfiber at conventional dosages. Project specifications requiring drying shrinkage reduction should combine the fiber with shrinkage-compensating cement, adequate moist curing, and joint layout per ACI 302.1R rather than relying on fiber addition alone.

    When Polypropylene Microfiber Is Added Under High-Alkali and Freeze-Thaw Exposure

    In high-alkali pore solutions, polypropylene homopolymer fibers are chemically inert and do not participate in the corrosion reactions associated with steel reinforcement. Immersion testing in saturated calcium hydroxide solution at 20 °C for 30 days typically shows retained tensile strength greater than 95% for virgin polypropylene filaments tested to EN 14889-2:2006. The product does not introduce chlorides or sulfates, and the hydrophobic surface limits water absorption below 0.1% by mass. These properties allow its use in concrete exposed to deicing salts, marine spray, and high-pH industrial environments without the rust staining or spalling risk associated with unprotected steel fiber.

    Freeze-thaw resistance is evaluated under ASTM C666/C666M-15 or EN 12390-9:2016 with air-entrainment parameters held constant. Polypropylene micro-synthetic fibers do not act as an air-entraining agent and must not replace air-entraining admixtures where frost exposure is expected. However, the dispersed fiber network can reduce the propagation of microcracks generated during freezing and thawing cycles and may improve the residual dynamic modulus of elasticity after 300 cycles compared with a non-fiber reference concrete. Published data for this specific configuration is limited; acceptance based on freeze-thaw performance should be verified through project-specific durability testing.

    Distinctions between SINTA M3106 and other fiber classes are defined by geometry, dosage, and hardened-state residual capacity. Micro-synthetic polypropylene fiber occupies the low-diameter, high-filament-count end of the concrete fiber spectrum. Its primary function is fresh-state crack control; it does not provide the post-crack flexural resistance measured in EN 14651:2005 or ASTM C1609/C1609M-19a beam tests. Macro-synthetic polypropylene fibers, with lengths from 30 mm to 60 mm and diameters above 0.3 mm, are added at 3 kg/m³ to 9 kg/m³ to increase post-crack residual strength in slabs-on-grade and sprayed concrete. Steel fibers at 20 kg/m³ to 80 kg/m³ provide residual flexural capacity approaching structural design values but add density of 7.85 g/cm³ and require attention to corrosion and pumping equipment wear. Compared with fibrillated micro-synthetic polypropylene fibers of similar length, the monofilament geometry of SINTA M3106 disperses as discrete filaments rather than opening into a network, which reduces the tendency to form fiber balls in low-slump mixes but provides slightly lower surface area per unit mass.

    Comparative fiber classes for cementitious mixtures
    AttributeSINTA M3106 micro-syntheticMacro-synthetic polypropyleneSteel fiber
    Typical cut length6 mm to 12 mm30 mm to 60 mm30 mm to 60 mm
    Filament diameter18 µm to 32 µm0.3 mm to 1.0 mm0.5 mm to 1.0 mm
    Density0.91 g/cm³0.91 g/cm³7.85 g/cm³
    Typical addition range0.6 kg/m³ to 1.8 kg/m³3 kg/m³ to 9 kg/m³20 kg/m³ to 80 kg/m³
    Primary functionPlastic shrinkage and settlement crack controlPost-crack control in non-structural slabs and shotcretePost-crack flexural reinforcement
    Residual flexural strengthNegligible at 0.9 kg/m³Moderate; measurable under EN 14651:2005High; specified by ASTM C1609/C1609M-19a
    Corrosion behaviorInert in alkaline concreteInertSurface corrosion possible unless alloyed or protected

    The difference in fiber count per kilogram is operationally significant. At 12 mm length and 22 µm diameter, SINTA M3106 contains approximately 2.4 × 10⁸ filaments per kg. Macro-synthetic fibers in the 40 mm length and 0.5 mm diameter class contain on the order of 10⁵ filaments per kg, and steel fibers at 60 mm length and 0.75 mm diameter contain on the order of 10³ to 10⁴ filaments per kg. This high filament count makes the micro-synthetic product effective in suppressing closely spaced early-age cracks but limits its ability to carry significant load across macro-cracks after concrete has hardened.

    Controlling Fiber Balls, Slump Loss, and Dose Verification in Ready-Mixed Concrete Production

    Quality control for SINTA M3106 in ready-mixed concrete begins with bag weight verification and visual inspection of fiber condition. The product should be stored in dry conditions at relative humidity below 60% to prevent fiber surface wetting that can cause static charge loss and agglomeration. Batch discharge sampled from the truck drum after 30 to 40 revolutions at mixing speed should be free of visible fiber balls larger than 10 mm in any dimension. When fiber balls are observed, the batching sequence should be changed to add the fiber earlier to the aggregate stream or to increase mixing time by 2 min to 3 min rather than increasing water content.

    For dose verification in fresh concrete, a washout procedure using a 0.15 mm sieve can extract fibers from a 10 kg sample. The recovered dry fiber mass should be within ± 5% of the calculated dosage. Air content tests under ASTM C231/C231M-23 are generally not affected at 0.9 kg/m³, but high-dose applications above 1.2 kg/m³ may require a correction check against the plain reference mixture. Batch-to-batch variability of cut length and diameter is governed by the manufacturer’s certificate of analysis, with length tolerance of ± 10% and diameter variation within ± 15%.

    In shotcrete and pumped concrete, the 6 mm cut length is recommended to reduce equipment blockages and rebound. Piston pumps with 50 mm to 75 mm line diameter and rotor-stator pumps have been used with addition rates up to 1.5 kg/m³ without modification to the pump circuit, provided the fiber is added to the mixer rather than post-added at the nozzle. For high-velocity dry-mix shotcrete, fiber integration may require a prebagged blend with the cementitious binder to maintain uniform fiber distribution in the feed stream.

    Published data for this specific configuration is limited in areas of tropical concreting at evaporation rates above 1.0 kg/m²/h. In such conditions, plastic shrinkage testing should be conducted with the project mix design rather than relying solely on general dosage tables.